1. Check level of electrolit which should be between "UPPER LEVEL" and "LOWER LEVEL" labels located on the case of the storage battery. |
2. If level is lower admissible, add the distilled water to "UPPER LEVEL" label. |
3. At small annual run of the car the density of electrolit is recommended to check each 3 months and to compare the received results to the data provided in the table. |
|
Above 25 ° With
|
Below 25 ° With
|
Completely charged battery
|
1,21-1,23
|
1,27-1,29
|
Charged for 70 %
|
1,17-1,19
|
1,23-1,25
|
The discharged
|
1,05-1,07
|
1,11-1,13
|
|
4. At suspicion on malfunction of the storage battery compare electrolit density in banks which should differ no more than on 0,04. Otherwise plates are damaged, or there is a leakage of electrolit. |
5. If the density differs in the specified limits, and the battery is discharged, it should be charged. |
|