Kia Sephia/Shuma/Spectra

since 1995 of release

Repair and car operation



KIA of Sefia / Noise/range
+ 2. Engine
+ 3. Greasing system
+ 4. Cooling system
+ 5. Power supply system and release
+ 6. Fuel system
+ 7. Ignition system
+ 8. Coupling
+ 9. Mechanical transmission
+ 10. Automatic transmission
+ 11. Axes and power shafts
+ 12. Steering
+ 13. Wheels and tires
+ 14. Brake system
+ 15. Suspension bracket
+ 16. Body
+ 17. Central air
- 18. Electric equipment
   18.1. Specifications
   18.2. Electric chains
   18.3. Safety locks
   18.4. Storage battery
   18.5. Check of level and density of electrolit and charging
   18.6. Unattended batteries
   18.7. Wires and plugs
   18.8. Charging of standard batteries
   18.9. Starter
   18.10. Switch of blocking of a starter
   18.11. Removal and starter installation
   18.12. Starter repair
   18.13. Check of the traction relay
   18.14. Check of brushes and shchetkoderzhatel
   18.15. Check of coils of a stator
   18.16. Rotor check
   18.17. Generator
   18.18. Belt of a drive of the generator
   18.19. Removal and generator installation
   18.20. Generator repair
   18.21. Check of a heater of back glass
   18.22. Safety cushion of the driver
   18.23. Safety cushion of the forward passenger
   18.24. Spiral wire
   18.25. Diagnostics of malfunctions of system of start-up and methods of their elimination
   + 18.26. Electric circuits


a7a4cf13

18. Electric equipment

GENERAL INFORMATION

The system of electric equipment of negative grounding has working tension of 12 volts. A food for system of electric equipment arrives from the lead-acid accumulator which is recharged from the generator.

It is necessary to notice that at work with any element of electric equipment of the car, the wire of the negative plug of the accumulator should be disconnected for prevention of short circuit and/or ignition.

Through regular intervals check an arrangement and fastenings of wires, watch that wires did not fray about other elements. If you find out that any wires rub about other elements, take wires aside and fix them so that it did not repeat.

Precautionary measures

It is forbidden to change polarity of a food of various devices and devices of the electric equipment in order to avoid failure of semi-conductor devices.

It is forbidden to disconnect and attach the storage battery, measuring devices and any wires on the working engine.

It is forbidden to check serviceability of the generator short circuit on mass of a power conclusion.