1. Remove a ware box. |
2. Start up the engine and leave to work at frequency of rotation of idling. |
3. Turn on the switch of the conditioner and establish for some minutes the fan switch on the highest frequency of rotation. |
4. Switch off the fan and stop the engine. |
5. Disconnect the socket of a thermoswitch of the conditioner. |
|
6. Additional wires connect the positive plug of the storage battery to contact of 1 socket and the negative plug – to contact 4 sockets. By the voltmeter measure tension on contacts 3 and 4 sockets. At temperature about 4 ° About tension it should be equal 12 In, and at temperature below 1 ° About tension 0 Century should be equal. |
7. Otherwise, replace conditioner thermocontact. |