| 1. Disconnect a wire from the negative plug of the storage battery. |
| 2. Lift up the diagnostic socket from the sensor of a measuring instrument of a consumption of air (MAF). |
| 3. Disconnect sockets of sensors of air temperature and a measuring instrument of a consumption of air. |
| 4. Remove the case of the air filter. |
| 5. Disconnect the socket of the sensor of frequency of rotation on entrances / turbines. |
| 6. Measure resistance between plugs 1 and 2. Resistance: 200–400 Ohm
|
| 7. Otherwise, replace the sensor of frequency of rotation with entrances / turbines. Inhaling moment: 8–11 N • m
|
| 8. Establish the air filter |
| 9. Connect sockets of sensors of air temperature and a measuring instrument of a consumption of air. |
| 10. Establish the diagnostic socket. |
| 11. Connect a wire to the negative plug of the storage battery. |