Kia Sephia/Shuma/Spectra

since 1995 of release

Repair and car operation



KIA of Sefia / Noise/range
+ 2. Engine
+ 3. Greasing system
+ 4. Cooling system
- 5. Power supply system and release
   5.1. Adjustment of a cable of an accelerator
   5.2. Check of a filtering element of the air filter
   5.3. Elements of system of production of the fulfilled gases
   5.4. A filtering element of the air filter
   5.5. Check of a corner of an advancing of ignition and frequency of rotation of idling
   5.6. Electronic control unit engine (ESM)
   5.7. Check of system of ventilation of a case (PCV)
   5.8. Check of system of catching паров fuels
   5.9. Check of the valve of system of catching паров fuels
   5.10. Separator check паров fuels
   5.11. Check of the bilateral valve of control
   5.12. Canister check with absorbent carbon
   5.13. Valve check паров fuels
   5.14. Sensor of measurement of a consumption of air (TED)
   5.15. Vacuum check
   5.16. Sensor of measurement of a consumption of air (TED)
   5.17. The sensor of temperature of cooling liquid
   5.18. Sensor of provision of a butterfly valve
   5.19. The warmed sensor of oxygen
   5.20. Check of forward and back warmed sensors of oxygen
   5.21. Main relay
+ 6. Fuel system
+ 7. Ignition system
+ 8. Coupling
+ 9. Mechanical transmission
+ 10. Automatic transmission
+ 11. Axes and power shafts
+ 12. Steering
+ 13. Wheels and tires
+ 14. Brake system
+ 15. Suspension bracket
+ 16. Body
+ 17. Central air
+ 18. Electric equipment


a7a4cf13

5.20. Check of forward and back warmed sensors of oxygen

PERFORMANCE ORDER
1. Switch off ignition.
2. Disconnect the socket of the sensor of oxygen.
3. Connect an ohmmeter between contacts 3 and 4 and measure resistance.

Resistance: 6 Ohm at 20°С

4. Otherwise, replace the oxygen sensor.

Inhaling moment: 30–49 N • m

5. Connect the socket to the oxygen sensor.

Removal

PERFORMANCE ORDER
1. Disconnect the socket from the warmed sensor of oxygen.
2. A special key turn out the sensor and remove it and a washer.

Installation

PERFORMANCE ORDER
1. Screw the oxygen sensor with a washer.

Inhaling moment: 30–49 N • m

2. Connect the socket to the oxygen sensor.